Error codes split system general climate. Error codes for all brands of air conditioners and split systems. GREE Air conditioners for semi-industrial, industrial use, - error codes


You can verify this yourself, all the functions of the air conditioner that do not work correctly are displayed on the display, the LED indicators blink in a certain order.
Good luck with your troubleshooting.
Fault codes Fujitsu, General Fujitsu. Which buttons to press and when? Split systems repair.
Which buttons to press and when? Split systems repair.
Fujitsu. Air conditioning trouble codes, system error control or System Controller Error.
When EE: EE is displayed on the remote remote control click "power saving" and
“Mode change button” at the same time hold the buttons for more than 3 seconds.
Error codes will be shown on the display.
(1) stop the air conditioner.
(2) Press the master control button and the fan control button at the same time for 2 seconds or more to start the test run
(3) Press the Start/Stop button to stop the test run
Self-diagnosis.

Press the temperature setting buttons for 5 seconds or more to start self-diagnosis.

With E error indication:
E.E. is displayed, follow the steps below to perform self-diagnosis.
E: EE indicates an error.
1. Remote control display
1) Stop the air conditioner.
2) Press the temperature setting buttons for 5 seconds or more to start self-diagnosis of the Fujitsu air conditioner.
Refer to the following table for a description of each Fujitsu error code.
(3) Press the temperature setting buttons for 5 seconds or more to stop self-diagnosis.
Error code = 00
wall split Fujitsu, General Fujitsu ASY, ASH, ASHB and ASYB systems malfunction of air conditioners. Includes Models AWHZ, AWYZ Nokia
Fujitsu ASY, ASH, ASHB and ASYB air conditioner malfunctions, error codes.
Content error = Communication error (indoor unit with remote controller)
Error code = 01
Malfunction = Communication error (indoor unit with outdoor unit)
Error code = 02
Fault = Fujitsu room temperature sensor open, open
Error code = 03
Fault = Indoor unit temperature sensor, - short circuit
Error code = 04
Fault = Fujitsu air conditioner indoor unit temperature sensor is open.
Error code = 05
Fault = Indoor unit temperature sensor is defective. Sensor resistance 10 Ohm.
Error code = 06
Fujitsu fault = outdoor heat exchanger temperature sensor open
Error code = 07
Malfunction = outdoor heat exchanger temperature sensor short circuit
Error code = 08
Fault = power to connect to the source of the error
Error code = 09
Fault = Float switch is working
Error code = 0A
Fault = Outdoor unit temperature sensor is open or open
Error code = 0b
Malfunction = Temperature sensor of the outdoor unit of the split system, - short circuit
Composite picture of service manual Fujitsu, General Fujitsu.
Composite picture of the service manual. Original.
Error code = 0c
Fault = Fujitsu temperature sensor tube open
Error code = 0d
Fault = Temperature sensor tube short circuit
Error code = 0E
Fault = Open high pressure abnormal
Error code = 0F
Fault = Temperature tube abnormal
Error code = 11
Fault = Model abnormal
Error code = 12
Malfunction = indoor unit fan abnormal
Error code = 13
Fault = no signal from Fujitsu, not normal
Error code = 14
Fault = no signal from room sensor
2.Fujitsu outdoor LED box.
When the outside temperature drops, there is not enough pressure in the system. Add freon.
error: heating and cooling (REVERSE CYCLE) wrong connection Fujitsu .
LED bulbs Fujitsu work as follows according to the content error.
Wall split systems Fujitsu, General Fujitsu ASY, ASH, ASHB and ASYB air conditioners malfunction.

Includes Models AWHZ, AWYZ Nokia

Red light = Off

Incorrect interconnection switching
Red light = Off

Connecting the outdoor unit fan, the wires are tangled. We confuse the pedals, pioneers.

Just a picture with diagrams. I didn't understand what was there. Some kind of fluff.
Red light = Off

Thermal sensor wire not connected
Red light = Off

Check voltage.
Red light = Off

remote control not working
Red light = 2 Flashes
Green timer indicator = 2 flashes
Closed temperature sensor
Fujitsu Red Light = 2 Flashing
Green timer indicator = 3 flashes
Closed humidity sensor
Red light = 3 Flashes
Green timer indicator = 2 flashes OD
Sensor resistance does not match
Red light = 3 Flashes
Green timer indicator = 3 flashes OD
Fujitsu moisture sensor pipe, short circuit.
Red light = 3 Flashes
Green timer indicator = 4 flashes OD
Temperature sensor failure, probably the Fujitsu sensor is dirty or damp, wet
Red light = 3 Flashes
Green timer indicator = 8 flashes
Compressor, - the temperature sensor has tripped, overheating. See the voltage in the network and the hall of the inter-block route.
Red light = 4 flashes
Green timer indicator = 2 flashes
Forced Automatic switching Fujitsu. Short circuit el. wires.

fujitsu error code, the entire model range. Differences by General Fujitsu models.
Red light = 4 flashes
Green timer indicator = 3 flashes
Main relay defective
Red light = 4 flashes
Green timer indicator = 4 flashes
Power failure, remove the batteries from the remote control, turn off the power to the air conditioner. wait 5 minutes. Next, insert the batteries, turn on the power. The air conditioner should work.
Red light = 4 flashes
Green timer indicator = 7 flashes
The Fujitsu overload protection has tripped. Check mains voltage
Red light = 4 flashes
Green timer indicator = 8 flashes
Broken wire, faulty socket.

Green timer indicator = 2 flashes
Not enough Fujitsu voltage, voltage drop. Call Chubais. Tel. easy to find on the internet.
Red Light = 5 Flashes
Green timer indicator = 3 flashes
Mains voltage reduced
Red Light = 5 Flashes
Green timer indicator = 5 flashes
The compressor does not turn on, the protection has tripped.
Fujitsu Red Light = 5 Flashes
Green timer indicator = 6 flashes
Open circuit fan ext. block.

Green timer indicator = 2 flashes
short circuit of the fan winding
Red Light = 6 Flashes
Green timer indicator = 3 flashes
Indoor unit fan speed error. Clean the fan from dirt, lubricate the bearing, replace the motor bearing, change the fan motor, throw it on the indoor unit, with anger before that, tap it well with a hammer, it helps. Calms the nerves and relieves stress. You can drink a little.
Red Light = 7 Flashes
Fujitsu timer green indicator = 2 flashes
High discharge temperature, overheating. Lack of freon gas. Add.
Red Light = 7 Flashes
Green timer indicator = 3 flashes
High pressure. A lot of gas, very hot - turn it down, set the pressure on the current clamps or look at the hall of the copper line.
Red Light = 7 Flashes
Green timer indicator = 5 flashes
Pressure sensor failure, not working.
Red light = 8 flashes
Green timer indicator = 2 flashes
Fujitsu filters clogged. Cleanse me. Well, finally open the panel of the indoor unit. Fucked up... gentlemen.
Red light = 8 flashes
Green timer indicator = 3 flashes
The error of the active filter is repeated after a while, see clogged filters.
Red Light Operation = 8 Flashes
Green timer indicator = 4 flashes
Fujitsu's brains don't work. Need processor firmware. It's cheaper to change the board right away.
Red Light = Operation Flashing
Green Light = Timer Flashing
Reversing valve Fujitsu. Knock, rattle, throw away, replace.

  • Technical Documentation Air Conditioners LG Electronics
  • Technical Documentation for Air Conditioners Aeronik
  • Technical Documentation Air-GREEN Air Conditioners
  • Technical Documentation Airwell Air Conditioners
  • Technical Documentation of Air Conditioners Ballu
  • Technical Documentation for Carrier Air Conditioners
  • Technical Documentation for Daikin Air Conditioners
  • Technical Documentation for Dantex Air Conditioners
  • Technical Documentation of Fuji Air Conditioners
  • Technical Documentation of Air Conditioners General
  • Technical Documentation of General Climate Air Conditioners
  • Gree Air Conditioner Technical Documentation
  • Tech Documentation for Haier Air Conditioners
  • Technical Documentation for Hitachi Air Conditioners
  • Tech Documentation Hyundai Air Conditioners
  • Technical Documentation of Kentatsu Air Conditioners
  • Technical Documentation for LENNOX Air Conditioners
  • Technical Documentation Lessar Air Conditioners
  • Technical Documentation Air Conditioners Midea
  • Mitsubishi Electric Air Conditioner Technical Documentation
  • Technical Documentation of Air Conditioners Mitsubishi Heavy Industries
  • Technical Documentation of Neoclima Air Conditioners
  • Codes Aeronik errors

    Error codes for air conditioners Aeronik (Aeronik)

    E1 - increased pressure in the discharge of the compressor;
    E2 - freezing of the heat exchanger of the indoor unit has occurred;
    E3 - the pressure in the compressor discharge has decreased;
    E4 - the temperature of the discharge pipeline has increased;
    E5 - operation of the compressor current relay;
    F0 - there are malfunctions in the air temperature sensor inside
    room, in the heat exchanger in the indoor unit or ambient air in the outdoor unit;
    F0 - There may also be a freon leak in the indoor unit.
    E6 - there were malfunctions in switching;
    E8 - the engine of the indoor unit is overloaded;
    F1 - there are malfunctions in the temperature sensor in the heat exchanger;
    F4 - there are malfunctions in the temperature sensor of the injected air
    air room.
    H1- is not an error. The air conditioner has switched to auto defrost mode.

    Airwell Error Codes

    Error codes for Airwell air conditioners (Airvel)



    Akvilon error codes

    Akvilon air conditioner error codes (Akvilon)

    Possible mistakes

    Monitor mode 1

    (indicator on

    display)

    Monitor mode 2

    (wiring controller)

    Appearance order

    Actions

    Communication error

    Shutdown

    Drainage system error

    The indicator lights up 4 times/8sec

    Shutdown

    Phase failure, phase failure or error low voltage

    The indicator lights up 6 times/8sec

    Shutdown

    The indicator lights up 1 time/8sec

    Shutdown

    Indoor unit sensor anomaly (TE)

    The indicator lights up 2 times/8sec

    Shutdown

    The indicator lights up 2 times/1sec

    Continue work

    Protection against internal overheating

    Shutdown

    Defrosting (not an error)

    Operation indicator lights up

    Continue work

    Fault codes for power supply 380-415W

    Suitable for 36000~60000BTU units, with 380-415W 3N, 50Hz power supply

    Possible mistakes

    Display mode1

    (Panel indicator

    display)

    Display Mode 2

    (indicator

    errors on the control panel)

    Display mode3

    (controller

    wires)

    Appearance order

    Actions

    Communication error

    Lights up 5 times and goes out after 2 seconds

    Shutdown

    Communication error with wire controller

    Shutdown

    Drainage system error

    Lights up 4 times and goes out after 2 seconds

    Shutdown

    External protection(Phase loss)

    Lights up 6 times and goes out after 2 seconds

    Shutdown

    External protection (discharge from overheating)

    Lights up 10 times and goes out after 2 seconds

    Shutdown

    High pressure protection

    Shutdown

    Low pressure protection

    Lights up 9 times and goes out after 2 seconds

    Shutdown

    Room temperature sensor anomaly (Air temperature)

    Lights up 1 time and goes out after 2 seconds

    Shutdown

    Indoor unit (TE) sensor anomaly

    Lights up 3 times and goes out after 2 seconds

    Shutdown

    Outdoor unit sensor anomaly (TW)

    Lights up 2 times and goes out after 2 seconds

    Lights up 2 times and goes out after 2 seconds

    Continue work

    Anomaly of the external condensate temperature sensor (TL)

    Lights up 7 times and goes out after 2 seconds

    Continue work

    Temperature Sensor Discharge Anomaly(TP)

    Lights up 8 times and goes out after 2 seconds

    Continue work

    Ballu Error Codes

    Error codes for air conditioners Ballu (Balu)


    E1 - short circuit or open circuit of the sensor responsible for the indoor unit.
    E2 - short circuit or open circuit of the sensor responsible for the temperature of the condenser.
    E3 - short circuit or open circuit of the sensor responsible for the temperature of the evaporator.
    E4 - short circuit or open circuit of the sensor responsible for the indoor unit.
    E6 - the protection of the external unit has tripped.
    E8 - electrostatic filter clogged.
    P4 - an error has occurred in the operation of the evaporator sensor due to high or
    low temperature.
    P5 - an error has occurred in the operation of the capacitor sensor due to high or
    low temperature.
    P6 - the defrost mode has been switched on or there has been a delay in operation
    heat exchanger.

    Carrier Error Codes

    Error codes for Carrier air conditioners


    2 - there were malfunctions of the temperature sensor in the room;
    3 - there were malfunctions of the temperature sensor in the internal
    heat exchanger;
    6 - there were malfunctions in the operation of the reversing valve in the outdoor unit;
    8 - there were malfunctions in the fan motor located in
    indoor unit;
    9 - no power supply of the indoor unit;
    11 - there were malfunctions in the drainage pump;
    12 - an error occurred software in the indoor unit;
    13 - an error occurred in the configuration;
    14 - lost signal in the central control system;
    15 - there were malfunctions of the temperature sensor in the internal
    heat exchanger;
    18 - there were malfunctions in the control of the outdoor unit;
    20 - the position of the block is not recognized;
    21 - there were malfunctions of the current sensor located in the outdoor unit;
    22 - there were malfunctions of the temperature sensor in the outdoor
    heat exchanger;
    23 - there were malfunctions of the discharge temperature sensor;
    24 - there were malfunctions in the operation of the fan in the outdoor unit;
    26 - other malfunctions in the outdoor unit;
    27 - the compressor located in the outdoor unit has blocked;
    28 - the value of the discharge temperature is unacceptable;
    29 - there were malfunctions in the compressor, located in the outdoor unit;
    31 - there was an increase in pressure in the circuit of the outdoor unit.

    Cooper&Hunter Error Codes

    Error codes for Cooper & Hunter air conditioners (Cooper & Hunter)

    Code E0 - exceeding the lower threshold of the starting voltage. Starting the frequency controller.
    Code E1 - overpressure. Starting the compressor protection system.
    Code E2 - the threat of freezing of the indoor unit. Launching the protection system.
    Code E3 - lowering the allowable pressure threshold. Starting the compressor protection system.
    Code E4 - exceeding the permissible temperature of the discharge tube. Launching the protection system.
    Code E5 - compressor overload. Launching the protection system.
    Code E6 - connection / operation error of the signal or power cable.
    Code E7 - the set modes of the split system do not match.
    Code E8 - evaporator overheating. Launching the protection system.
    Code E9 - start of the cold air protection system in thermal mode.
    Code F0 - failure of the temperature discharge sensor.
    Code F1 - failure of the evaporator temperature sensor.
    Code F2 - failure of the condenser temperature sensor.
    Code F3 - failure of the air temperature sensor in the system.
    Code F4 - failure of the supercharger temperature sensor.
    Code F5 - failure of the compressor discharge tube sensor.
    Code F6 - condenser overheating.
    Code F7 - there is not enough lubrication in the compressor crankcase.
    Code F8 - the compressor is overloaded. Launching the protection system.
    Code F9 - exceeding the maximum condenser temperature due to a decrease in fan speed during cooling. The compressor is overloaded.
    Code FF - there is no power supply to one of the phases / an error in the operation of the phase monitor.
    Code FA - condenser/evaporator superheat. Launching the protection system.
    Code FH - evaporator freezing threat. Launching the protection system.
    Code H0 - overheating protection is activated.
    Code H1 - condenser defrost mode is activated.
    Code H2 - an error in the operation of the electrostatic filter. Launching the protection system.
    Code H3 - exceeding the permissible temperature of the compressor. Launching the protection system.
    Code H4 - an error in the system.
    Code H5 - start the protection system of the inverter unit IPM.
    Code H6 - sensor malfunction. Lost return signal from fan motor.
    Code H7 - the compressor is faulty.
    Code H8 - the drainage system is overflowing. Start protection.
    Code H9 - malfunction of the electric heater of the indoor unit.

    Daikin error codes

    Error codes for Daikin air conditioners (Daikin)


    A0 - safety device tripped.
    A1 - PCB failure.
    A2 - the fan motor is blocked.
    A3 - abnormal level of drainage.
    A4 - malfunctions in the heat exchanger.
    A5 - abnormal temperature in the heat exchanger.
    A6 - the fan motor is overloaded.
    A7 - Faulty shutter drive.
    A8 - current overload of the device.
    A9 - expansion valve is defective.
    AA - engine overheated.
    AH - air filter contamination.
    AC - idling is fixed.
    AJ - insufficient performance.
    AE - weak water supply.
    AF - humidifier defect detected.
    C0 - the sensor is faulty.
    C3 - the sensor responsible for the drainage system is faulty.
    C4 - the sensor responsible for the temperature of heat exchanger 1 is faulty.
    C5 - the sensor responsible for the temperature of heat exchanger 2 is faulty.
    C6 - the fan motor is overloaded.
    C7 - the sensor responsible for the blind drive is faulty.
    C8 - the sensor responsible for the input current is faulty.
    C9 - Faulty inlet air thermistor.
    CA - the outlet air thermistor is defective.
    CH - high level of pollution.
    CC - humidity sensor is defective.
    CJ - the temperature sensor located on the control panel is faulty.
    CE - the radiation sensor is defective.
    CF - the sensor responsible for high pressure is faulty.

    Error codes for the outdoor unit of Daikin air conditioners (Daikin)

    E0 - a protective device has tripped.
    E1 - the printed circuit board located in the outdoor unit is faulty.
    E3 - triggering of the sensor responsible for high pressure.
    E4 - triggering of the sensor responsible for low pressure.
    E5 - overheating relay or compressor motor overloaded.
    E6 - the compressor motor is blocked.
    E7 - the fan motor is blocked.
    E8 - current overload detected.
    E9 - the expansion valve is faulty.
    AH - a pump blockage has occurred.
    EJ - operation of an additional protective device.
    EE - exceeded in the drainage system allowable level water.
    EF - the unit responsible for the accumulation of heat is faulty.
    H0 - general malfunction of the sensors.
    H1 is the sensor responsible for air temperature, faulty.
    H2 - the sensor responsible for the electrical supply is faulty.
    H3 - the sensor responsible for high pressure is faulty.
    H4 - the sensor responsible for low pressure is faulty.
    H5 - activation of the overload sensor or the compressor does not work.
    H6 - activation of the blocking sensor or the compressor is overloaded.
    H7 - activation of the blocking sensor or the fan is overloaded.
    H8 - triggering of the sensor responsible for the input voltage.
    H9 - triggering of the sensor responsible for the outdoor temperature.
    HA - triggering of the sensor responsible for the outlet air.
    HH - triggering of the sensor responsible for blocking the water pump.
    HС - triggering of the sensor responsible for hot water.
    HE - triggering of the sensor responsible for the drainage system.
    HF - an accident has occurred in the heat storage unit.
    F0 - actuation of devices No. 1 and No. 2, responsible for protection.
    F1 - actuation of device No. 1, which is responsible for protection.
    F2 - actuation of device No. 2, which is responsible for protection.
    F3 - too high temperature in the discharge pipe.

    Dantex Error Codes

    Error codes for Dantex air conditioners (Danteks)


    E1 - an error occurred in the non-volatile memory;
    E2 - there was a zero crossing error;
    E3 - no control of the fan speed of the indoor unit;
    E4 - the overvoltage protection mode is in effect;
    E5 - there is no contact with the control of an open temperature sensor;
    E6 - there is no contact with the control of the evaporator temperature sensor.

    Chillers Dantex (DN)

    E0 - an error occurred in the operation of the water flow meter;
    E1 - an error occurred when connecting the phases;
    E2 - a communication error has occurred;
    E3 - an error has occurred in the outlet water temperature sensor;
    E4 - an error has occurred in the temperature sensor of the water at the outlet of
    shell and tube heat exchanger;
    E5 - an error in the operation of capacitor A;
    E6 - an error in the operation of the capacitor B;

    E8 - an error has occurred in the charge air temperature sensor;
    E9 - an error occurred in the flowmeter;
    EA - the main block revealed a decrease in the number of additional blocks;
    EB - malfunctions of the frost protection system;
    EC - failures in the operation of the drive controller;
    ED - an error occurred in the control system and communication between the blocks;
    Ed - operation of electrical protection;
    EE - an error has occurred in the connection between the microprocessor and the control panel;
    EF - an error occurred in the inlet water temperature sensor;
    RO - overheating or increased pressure;

    P2 - increased pressure or overheated air in system B;
    P3 - the pressure in the system has decreased;
    P4 - there was an overcurrent in system A;
    P5 - there was an overcurrent in system B;
    P6 - increased pressure in the condenser of system A;
    P7 - increased pressure in the condenser of system B;
    P8 - malfunctions in the operation of the compressor discharge temperature sensor in system A;
    Pb - frost protection;
    PE - the temperature in the heat exchanger has decreased;
    F1 - errors in the work of permanent memory;
    F2 - errors in the operation of wired controllers.

    Elektrolux error codes

    Error codes for Elektrolux air conditioners (Electrolux)


    E1 - the pressure level is exceeded;
    E2 - the indoor unit has frozen;
    E3 - too low level pressure;
    E4 - malfunctions of the compressor;
    E5 - an overcurrent has occurred;
    E6 - there is no connection between the indoor and outdoor units;
    E7 - there was a conflict in the operating modes of the indoor units;
    E8 - the fan of the indoor unit is overloaded;
    E9 - the drainage bath is overflowing;
    F0 - malfunctions in the operation of the temperature sensor in the indoor unit;
    F1 - malfunctions in the operation of the temperature sensor inlet to the heat exchanger
    in the indoor unit;
    F2 - malfunctions in the operation of the temperature sensor in the middle part

    F3 - malfunctions in the operation of the temperature sensor at the outlet of
    heat exchanger in the indoor unit;
    F4 - malfunctions in the operation of the ambient air temperature sensor;
    F5 - malfunctions in the operation of the temperature sensor of the outdoor unit;
    F6 - malfunctions in the operation of the temperature sensor inlet to the heat exchanger
    in the outdoor unit;
    F7 - malfunctions in the operation of the temperature sensor of the exit from
    heat exchanger in the indoor unit;
    F8 - malfunctions in the operation of the discharge temperature sensor of the first
    compressor;
    F9 - malfunctions in the operation of the discharge temperature sensor of the second
    compressor;
    FA - malfunctions in the operation of the crankcase temperature sensor of the 1st compressor;
    FB - malfunctions in the operation of the crankcase temperature sensor of the 2nd compressor;
    FC - malfunctions in the operation of the high pressure sensor;
    FD - malfunctions in the operation of the low pressure sensor;
    EH - malfunctions in the operation of the additional heater.

    Fuji Error Codes

    Error codes for Fuji air conditioners (Fuji)


    E00 - an error occurred in the connection of the remote control with the indoor unit;
    E01 - an error occurred in the connection between the indoor and outdoor modules;
    E02 - malfunctions of the room temperature sensor;
    E03 - a short circuit has occurred on the room temperature sensor;
    E04 - an error occurred in the operation of the temperature sensor on the internal
    heat exchanger;
    E05 - a short circuit has occurred on the temperature sensor of the internal
    heat exchanger;
    E06 - an error occurred in the operation of the temperature sensor on the outdoor
    heat exchanger;
    E07 - a short circuit has occurred on the outdoor temperature sensor
    heat exchanger;
    E08 - the supply of electrical energy is interrupted;
    E09 - there was an overflow of the tank intended for collecting condensate;
    E0R - malfunctions in the operation of the temperature sensor of the outdoor unit;
    E0B - a short circuit has occurred on the temperature sensor of the outdoor unit;
    Е0С - opening of the temperature sensor on the drain pipe is required;
    E0D - a short circuit has occurred on the temperature sensor of the drain pipe;
    E0F - the output temperature is too high or too low;
    E11 - malfunctions of the control board;
    E12 - malfunctions of the fan of the indoor unit;
    E13 - giving incorrect signals by the system;
    E14 - error in non-volatile memory.

    General Climate Error Codes

    Error codes for General Climate air conditioners (General Climate)


    E2 - short circuit or open circuit of the sensor responsible for the temperature of the internal
    air.
    E3 - short circuit or open circuit of the sensor responsible for the temperature of the evaporator.
    E4 - short circuit or open circuit of the sensor responsible for the temperature of the condenser.
    E5 - an error has occurred in the operation of the drainage pump.
    E6 - an error in the protection of the external unit.
    E7 - An EEPROM error has occurred.
    E8 - the overflow protection of the drain pan has tripped.

    Gree Error Codes

    Error codes for Gree air conditioners (Gri)


    E1 - the compressor protection against too high pressure has tripped.
    E2 - the frost protection of the indoor unit has worked.
    E3 - the compressor protection against too low pressure has tripped.
    E4 - the protection of the injection tube against high temperature has tripped.
    E5 - the protection of the system or compressor against overloads has worked.
    E6 - problems have been detected in the signal or power cables.
    E7 - contradictions in the established mode.
    E8 - the protection of the electric motor or evaporator against overheating has tripped.
    E9 - protection against cold air entry during heating has worked.
    E0 - protection of the frequency controller from too low starting
    voltage.
    H6 - no feedback from the fan motor.
    F0 - the temperature discharge sensor is faulty.
    F1 - the sensor responsible for the evaporator temperature is faulty.
    F2 - the sensor responsible for the temperature of the condenser is faulty.
    F3 - the sensor responsible for the air temperature in the system is faulty.
    F4 - the sensor responsible for the temperature of the supercharger is faulty.
    F5 - the sensor responsible for the compressor discharge pipe is faulty.
    F6 - Capacitor overheating detected.
    F7 - oil carryover from the compressor is detected.
    F8 - protection of the system or compressor from overloads has worked.
    F9 - the compressor protection against high temperatures has worked.
    FF - no power in one of the phases or the phase monitor is faulty.
    H1 - defrosting is in progress.
    H2 - protection of the electrostatic filter has tripped.
    H3 - protection against severe overheating has tripped.
    H4 - A system failure has occurred.
    H5 – IPM block protection operation.
    H7 - malfunctions in the compressor.
    H8 - operation of the drainage system protection against overflow.
    H9 - electrical heater malfunctions.
    H0 - overheat protection trip.
    FA - operation of the condenser or evaporator protection against overheating.
    FH - activation of the evaporator frost protection.

    Green Error Codes

    Error codes for Green air conditioners (Green)


    U1 - Current phase fault, circuit detection for compressor. Flashes 13 times. During cooling and drying operation, the compressor will stop while the indoor fan is running. When running in heating mode, the full unit will stop. Replacement of the external control panel AP1.

    U3 - Malfunction voltage dropping on the DC bus. Flashes 20 times. During cooling and drying operation, the compressor will stop while the indoor fan will run; When operating in heating mode, the full unit will stop.
    The supply voltage is unstable.

    U5 - Malfunction of the full unit of current detection. Flashes 13 times. During cooling and drying operation, the compressor will stop while the internal fan is running; During heating operation, the full block will stop the operation. There is a circuit malfunction on the outdoor units control panel AP1, please replace the outdoor unit control panel AP1.

    U7 - Blinks 20 times. If this fault occurs during heating operation, the device will stop working. 1. The power supply voltage is lower than AC175V; 2. Wiring terminal 4V is loose or broken; 3. 4V will be damaged, please replace the cable.

    U8 - Zero transition inspection circuit malfun-fiction Fan pin moto. Flashes 17 times every 3s Remote controller operation or
    the control panel is available, but the units will not function. The discharge rate of the capacitor is slow, which lead wrong decision controller. Zero crossing detection circuit of the main board abnorma. Refer to flowchar repair.

    U9 - Zero crossing outdoor unit malfunction. Flashes 18 times. During cooling operation, the compressor will stop when the indoor fan is running; during heating, the device will not work. Replacement of the external control panel AP1.

    Haier Error Codes

    Error codes for Haier air conditioners (Haer)

    E0 Violation of the condensate drain function.
    E1 The compressor is pressurized.
    E2 The heat exchanger of the indoor unit is covered with ice.
    E3 Insufficient pressure in the compressor.
    E4 Compressor overheating.
    E5 Compressor disabled due to increased load.
    E6 No communication between blocks.
    E7 The indoor unit does not respond to commands from the remote control.
    E8 Indoor unit motor overload.
    F0 The temperature sensor in the room has turned off.
    F1 The temperature sensor of the heat exchanger of the indoor unit has turned off.
    F2 Heat exchanger temperature sensor turned off external module.
    F3 The outdoor temperature sensor has switched off.
    F4 The temperature sensor on the air supply has switched off.
    FF Power failure.

    Hisense Error Codes

    Error codes for Hisense air conditioners (Hysens)

    Possible reasons faults:
    1 Outdoor unit heat exchanger temperature sensor error a. Outdoor unit heat exchanger temperature sensor circuit open; b. Faulty outdoor unit heat exchanger temperature sensor; With. Faulty outdoor unit control circuit board
    2 Compressor discharge temperature sensor error a. The temperature sensor circuit in the compressor discharge line is open; b. Faulty temperature sensor in the compressor discharge line; With. Faulty outdoor unit control circuit board
    5 Integrated Power Module (IPM) protection trip a. Faulty integrated power module (IPM) circuit board; b. The fan of the outdoor unit is out of order; c. Faulty outdoor unit fan motor; d. Outdoor unit fan blocked; e. Condenser dirty; f. The installation instructions for the outdoor unit are not followed.
    6 AC overvoltage or undervoltage protection tripped a. The voltage in the network is above or below the maximum permissible values; b. The power supply voltage of the unit is above or below the maximum permissible values
    7 Communication error between indoor and outdoor units a. Breakage of the connecting cable; b. Connecting cable damaged; With. Wrong connection or broken connection between filter board and outdoor unit control PCB
    8 Overload protection device a. Fan motor failure; b. The evaporator and condenser are dirty; c. The air intake and air outlet are blocked; d. Faulty printed control of the outdoor unit; e. Compressor defective
    10 Communication error between two microcircuits (control and drive) in the printed circuit a. Poor cable connection b. Faulty outdoor unit PCB or drive circuit board;
    11 Outdoor unit EEPROM memory error a. Poor soldering of the EEPROM chip; b. EEPROM chip installation error (wrong position); .EEPROM chip failure
    12 Operation of the protection device at low outdoor temperatures a. This protection triggered if the outdoor temperature drops below 15°C; b. Faulty outdoor temperature sensor; With. Faulty outdoor unit control PCB.
    13 Safety device tripped due to overtemperature at a. Faulty temperature sensor in the compressor discharge line; b. Insufficient refrigerant charge in the system
    14 Outside air temperature sensor error a. Open circuit of the outdoor temperature sensor; b. Faulty outdoor temperature sensor; With. Faulty outdoor unit control circuit board
    15 Compressor thermal overload trip a. Compressor discharge temperature sensor circuit open b. Insufficient refrigerant charge in the system
    16 Heat exchanger frost protection or overload protection operation during indoor unit heating operation a. Regular operation of the protection device in case of freezing of the heat exchanger or overloads; b. Indoor heat exchanger temperature sensor circuit open; c. Faulty indoor unit heat exchanger temperature sensor; d. Faulty indoor unit control circuit board; e. Refrigerant circulation disorder
    17 Power Factor Compensation (PFC) a. Faulty reactive power compensation device; b. Faulty outdoor unit drive circuit board
    18 DC compressor start error a. Incorrect connection or breakage of the compressor power cable; b. The circuit board of the integrated power module (IPM) of the outdoor unit is defective; c. Faulty outdoor unit control PCB d. Compressor defective
    19 Compressor drive error a. Incorrect connection or breakage of the compressor power cable; b. The circuit board of the integrated power module (IPM) of the outdoor unit is defective; c. Faulty outdoor unit control PCB d. Compressor defective 7. Troubleshooting
    20 Locked-rotor outdoor fan motor protection tripped a. Outdoor unit fan motor circuit open; b. Outdoor unit fan blocked; With. Faulty fan motor; d. Faulty outdoor unit control circuit board

    Hitachi Error Codes

    Error codes for Hitachi brand air conditioners (Hitachi)


    01 - malfunction of the reversing valve or out of order
    media temperature.
    02 - the mode is activated, forcibly starting the external module.
    03 - there is no communication between the external and internal module.
    04 - equipment malfunctions, you should pay attention to the readings
    other indicators.
    06 - violations were detected in the operation of the pump, which pumps out condensate.
    07 - requires manual start of the pump.
    08 - engine functions are violated.
    09 - no communication with the PCB thermistor.
    10 – incorrect work fan.
    13 - PCB does not function.

    Hyundai error codes

    Error codes for Hyundai air conditioners (Hyundai)

    0 – error in non-volatile memory;
    E1 - an error occurred in the connection of the blocks: indoor and outdoor;
    E2 - malfunctions of the sensor of the outdoor unit;
    E3 - malfunctions of the fan motor of the indoor unit;
    E4 - an open (short circuit) of the indoor air temperature sensor has occurred;
    E5 - there was a break (short circuit) of the evaporator temperature sensor;
    EC - A coolant leak has occurred.

    Jax error codes

    Jax Air Conditioner Error Codes (Jax)


    E2 - there were malfunctions in the indoor air temperature sensor;
    E3 - there are malfunctions in the evaporator temperature sensor;
    E4 - there are malfunctions in the condenser temperature sensor;
    E5 - an error occurred in the operation of the drainage pump;
    E6 - protection in the external unit has tripped;
    E7 - failures in non-volatile memory;
    E8 - the drain pan is full.

    Kentatsu Error Codes

    Error codes for Kentatsu air conditioners (Kentatsu)


    E1 - there is no contact with the air temperature sensor in the internal
    block;
    E2 - there is no contact with the temperature sensor of the evaporator;

    E4 - there is no contact with the outdoor air temperature sensor;
    E5 - there is no contact between the indoor and outdoor unit;
    E6 - warning of overheating or freezing of the outdoor module;
    E10 - there was a pressure failure in the compressor;
    E13 - no electricity is supplied due to tangled wires;
    E14 - supply of electricity to the wrong phase;
    P4 - the evaporator has overheated;
    P5 - the capacitor has overheated;
    P7 - exceeding the temperature level in the compressor;
    P9 - frost protection turned on;
    P10 - the value of the air at the outlet is incorrect;
    P11 - the air intake pressure exceeds allowable norms;
    P12 - supply of high voltage current;
    HS - defrosting of the outdoor module is in progress.
    EC - Freon leak.

    Models Kentatsu (Kentatsu) KSGH/KSRH

    E1 - errors occurred in non-volatile memory;
    E2 - there was a failure in the process of transformation of the zero cycle;
    E3 - incorrect rotation of the fan;
    E4 - supplying too high voltage to the compressor;
    E5 - there was a violation of communication with the temperature sensor of the air inside;
    E6 - there was a communication failure with the evaporator temperature sensor.

    Models Kentatsu (Kentatsu) KSFU/KSRU

    P4 - the evaporator of the indoor module has overheated;
    P5 - the condenser of the outdoor module has overheated;
    P9 - thawing is in progress;
    E1 - no voltage to temperature sensors;
    E2 - there is no connection with the temperature sensor of the evaporator;
    E3 - there is no contact with the temperature sensor of the condenser;
    E6 - there are malfunctions in the external module.

    Channel type air conditioners

    E0 - malfunctions of the temperature sensor in the room;
    E1 - there were malfunctions in the operation of the evaporator temperature sensor;
    E2 - there are malfunctions in the temperature sensor of the external module;
    E3 - there is no connection with the outdoor module;
    E4 - there were malfunctions in the condenser pump;
    E5 - errors in non-volatile memory;
    E6 - the condensate collection pan is full.

    Lessar Error Codes

    Error codes for Lessar air conditioners (Lessar)


    E0 - an error has occurred in the flow sensor;
    E1 - wrong phase sequence;
    E2 - a communication error has occurred;
    E3 - an error has occurred in the direct water temperature sensor;
    E4 - an error has occurred in the temperature sensor of the shell-and-tube heat exchanger;
    E5 - an error has occurred in the temperature sensor of the condenser pipe A;
    E6 - an error has occurred in the temperature sensor of the condenser pipe B;
    E7 - an error has occurred in the outdoor air temperature sensor;
    E8 - an error has occurred in the compressor discharge temperature sensor
    systems A;
    E9 - an error has occurred in the flow temperature sensor;
    EA - there was a loss of communication with the slave units;
    P0 - pressure or temperature in system A is exceeded;
    P1 - pressure in system A has decreased;
    P2 - the pressure or temperature in the system B is exceeded;
    P3 - pressure in system B has decreased;
    P4 - there was an excess of current in system A;
    P5 - there was an excess of current in system B;
    P6 - the condensation temperature in system A is exceeded;
    P7 - the condensing temperature in system B is exceeded;
    P8 - temperature rise in the compressor;
    Pb - frost protection.

    LG error codes

    Error codes for LG air conditioners (Algy)


    01 - there was a short circuit in the sensor responsible for the air temperature,
    or broken circuit.
    02 - a short circuit occurred in the sensor responsible for the temperature
    evaporator, or open circuit.
    03 - a bad connection between the drive console and
    indoor unit.
    04 - an error occurred in operation drainage pump or float
    sensor responsible for the level of condensate.
    05 - fixed error of interconnection of internal and external
    blocks.
    06 - a short circuit occurred in the temperature sensor responsible for the outdoor
    block or open circuit.
    07 - indoor multi-system units operate in different modes.
    HL - the float sensor has opened.
    CL - child lock is activated.
    Po - the device operates in jet cool mode.

    MDV error codes

    Error codes for air conditioners MDV (MDV)


    Free Match Series
    Error indication on the indoor unit


    Fault codes on the outdoor unit

    Universal outdoor unit

    30, 36, 48, 60 Btu/h three-phase power models



    Midea Error Codes

    Error codes for Midea air conditioners (Midea)


    E0 - an error occurred in the non-volatile memory of the indoor unit.
    E1 - an error occurred in the connection of the outdoor and indoor units.
    E2 - an error occurred during the transition through zero.
    E3 - an error occurred during the operation of the fan motor.
    E4 - short circuit or open circuit of the sensor responsible for the temperature of the internal
    air.
    E5 - short circuit or open circuit of the sensor responsible for the temperature of the evaporator.
    EC - a refrigerant leak has been detected.

    Mitsubishi Electric Error Codes

    Mitsubishi Electric Air Conditioner Error Codes (Mitsubishi Electric)


    P1 - an error of sensors at the input is fixed.
    P2 - an error in the operation of the sensor responsible for the TH5 heat exchanger.
    P4 - the drain pan is full or the CN4F sensor has broken.
    P5 - An error has occurred in the drain pump.
    P6 - overheating or freezing has occurred.
    P9 - an error in the operation of the sensor responsible for the TH2 heat exchanger.
    PA - the compressor is forced to stop.
    E0, E3 - lost connection with the control panel.
    E1, E2 - problems in the control board.
    E9, EE - there is no communication between the outdoor and indoor unit.
    U1. Ud - overheating protection has tripped, or the 63H sensor has fixed
    high pressure.
    U2 - low pressure in the supercharger, not enough refrigerant.
    U3, U4 - short circuit or open circuit in the temperature sensor of the outdoor unit.
    U5 - the temperature of the condenser does not correspond to the norm.
    U6 - a forced stop of the compressor or a malfunction has been detected
    power module.
    U7 - lack of refrigerant or low pressure in the supercharger.
    U8 - the motor of the fan installed on the outdoor unit has stopped.
    U9, UN - reduced or overvoltage power, or a problem with
    current sensor.
    UF - the compressor is stuck or a current overload is detected.
    UP - compressor stopped due to overload.
    Fb - problems in the control board of the external unit.

    Mitsubishi Heavy error codes

    Error codes for Mitsubishi Heavy air conditioners (Mitsubishi Heavy)


    E1 - there was a malfunction in the printed circuit board of the indoor unit or there were
    malfunctions in the control panel;
    E2 - there was a duplication of addresses of indoor units;
    E3 - the address of the outdoor unit is incorrect;
    E5 - there were malfunctions in the control board of the outer side;
    E6 - an open (short circuit) of the evaporator sensor has occurred;
    E7 - there was a break (short circuit) of the sensor of the indoor unit;
    E8 - an evaporator overload has occurred;
    E9 - an error in the operation of the drainage pump;
    E10 - more than 16 blocks are connected to the control panel;
    E11 - more than 1 block is connected to the control panel when the address is occupied;
    E12 - errors in the address settings;
    E14 - incorrect settings of the master and slave connections were made;
    E16 - there were malfunctions in the operation of the fan of the indoor unit;
    E28 - there were malfunctions in the sensor of the control panel;
    E30 - an error occurred in the connection of the outdoor and indoor units;
    E31 - incorrect address settings;
    E32 - a wire break has occurred or the phase sequence has been incorrectly performed;
    E33 - there was a break in the winding of the wire;
    E34 - the phase of the winding has opened;
    E35 - malfunctions in the operation of the sensor or an increase in temperature in
    condenser;
    E36 - there was a deviation in the temperature of the outlet air above the norm;
    E37 - there were malfunctions in the condenser temperature sensor;
    E38 - there were malfunctions in the outdoor air temperature sensor;
    E39 - there were malfunctions in the temperature sensor of the discharge pipe;
    E40 - there was an increase in pressure in the system;
    E49 - a decrease in pressure has occurred or the refrigerant is not enough;
    E53 - there were malfunctions in the thermistor of the suction pipe;
    E54 - the low pressure sensor is disconnected;
    E55 - there are malfunctions in the temperature thermistor inside the compressor;
    E56 - there were malfunctions or a break in the temperature sensor of the power
    transistor;
    E57 - insufficient amount of coolant;
    E59 - the compressor does not start;
    E60 - an error occurred in the positioning of the compressor;
    E63 - an emergency shutdown of the indoor unit has occurred.

    Neoclima error codes

    Error codes for Neoclima air conditioners (Neoclima)

    Code E0 - an error in connecting the indoor and outdoor units.
    Code E1 - an error in the operation of the indoor unit. Disruption of communication with the controller.
    Code E2 - an error in the operation of the temperature sensor.
    Code E3 - the temperature sensor of the condenser tube is defective.
    Code E8 - violations in the operation of the heating system.
    Code F0 - an error in the operation of the internal fan.
    Code F2 - the external protection system has worked.
    Code F3 - protection in the high pressure system has tripped.
    Code F4 - protection in the low pressure system has tripped.
    Code F5 - water overflow protection has tripped.
    Code F8 - protection against overheating of the outdoor unit has worked.
    Code F9 - incorrect phase sequence. Error in the system.
    Code P4 - compressor inverter air conditioner out of order.
    Code P6 - an error in the operation of the outdoor unit EEPROM.

    Panasonic error codes

    Error codes for Panasonic brand air conditioners (Panasonic)


    H00 - no problems found.
    H11 - no communication between the outdoor and indoor unit or malfunction
    control boards.
    H12 - the power of the indoor units does not match the outdoor one.
    H14 - short circuit of the air sensor.
    H15 - short circuit of the sensor responsible for the temperature of the compressor.
    H16 - lack of freon in the external unit or the current circuit is broken
    board transformer.
    H17 - breakage of the sensor responsible for the temperature on the tube,
    designed to dry the refrigerant.
    H19 - the board, fan motor or connectors are jammed
    wires.
    H21 - Faulty or clogged float sensor drainage system.
    H23 - sensor 1 is broken, which is responsible for the temperature of the evaporator.
    H24 - sensor 2 is broken, which is responsible for the temperature of the evaporator.
    H25 - malfunctions in the ionization unit or internal board.
    H26 - the ionizer has failed.
    H27 - short circuit of the sensor responsible for the temperature of the outdoor air.
    H28 - short circuit of the sensor responsible for the temperature of the condenser.
    H30 - the sensor responsible for the discharge temperature is broken.
    H32 - short circuit of the sensor responsible for the temperature of the condenser at the outlet.
    H33 - An error has occurred in the interconnection.
    H34 - short circuit of the sensor responsible for the temperature of the module heatsink.
    H35 - a pump malfunction or drain blockage has been detected.
    H36 - short circuit of the sensor responsible for the temperature of the gas pipe.
    H37 - short circuit of the sensor responsible for the temperature of the liquid tube.
    H38 - a discrepancy between the outdoor and outdoor unit has been detected.
    H39 - freon circuits and wires are mixed up, or does not work
    solenoid valve.
    H41 - wires are connected incorrectly.
    H50 - malfunctions in the board or fan motor.
    H51 - The nozzle is clogged.
    H52 - the limiter switch is defective.
    H58 - Patrol Sensor unit is defective.
    H64 - the sensor responsible for high pressure is faulty.
    H97 - malfunctions in the compressor motor or indoor unit board.
    H98 - Faulty overheating protection.
    H99 - evaporator freezing has been detected.
    F11 - the four-way valve does not work correctly.
    F17 - the indoor unit is frozen.
    F90 - the compressor winding is broken.
    F91 - the refrigeration circuit is not working correctly.
    F93 - the compressor winding is broken.
    F94 - high pressure blower protection does not work.
    F95 - the heat exchanger of the outdoor unit has overheated.
    F96 - the power module has overheated.
    F97 - Compressor temperature exceeded.

    Pioneer error codes

    Error codes for Pioneer air conditioners (Pioneer)

    Air conditioner error code Pioneer Yellow diode Green diode
    Red diode

    Deciphering Pioneer Air Conditioner Errors
    E0 * The function of the discharge temperature sensor is broken
    E6 * The function of the capacitor temperature sensor is broken
    E6 * The function of the outdoor air temperature sensor is broken
    E1 * The function of the temperature sensor in the room is broken
    E2 * The function of the evaporator temperature sensor is broken
    E3 m m m Indoor unit fan broken
    E4 m * IPM system failure
    E5 m m Power failure
    E8 * mm m Voltage supply failure
    E9 m Compressor started incorrectly
    EA * Incorrect communication with the outdoor unit
    EU m * The air conditioner is supplied with an electric current of invalid parameters
    EE EEPROM failure
    EP No communication between outdoor and indoor units
    P0 The unit did not start correctly
    P1 Discharge superheat
    P2 Increased current in the circuit
    P3 Too high voltage online
    P4 mm * No communication with the current relay
    P5 Evaporator overheat
    P6 Condenser overheating
    P7 Matrix protection IPM
    * - the diode is lit, m - the diode is blinking.

    Error codes for Pioneer air conditioners of the external module:

    Pioneer air conditioner error code (number of diode blinks) Pioneer air conditioner error decoding
    1 No communication with external temperature sensor
    2 No communication with the condenser temperature sensor
    3 No connection with discharge temperature sensor
    4 Mains current too high
    5 Mains voltage too high
    7 No communication with indoor unit
    9 The unit was not started up correctly
    12 Mains voltage too high
    13 IPM board protection
    16 Compressor overtemperature
    17 Discharge temperature too high
    18 Condenser temperature too high
    19 IPM board malfunction
    20 Communication error between indoor and outdoor units
    22 Deicing

    Quattroclima error codes

    Error codes for Quattroclima air conditioners (Quattroclima)

    Error or task
    RUN indicator
    Digital
    display
    Cause and troubleshooting
    Switching to defrost mode
    Flashes 1 time per second
    dF
    Is not an error.

    Cold air prevention
    Flashes 1 time per 3 seconds
    Indoor unit fan does not rotate This is not an error.
    Service function of the air conditioner and its settings cannot be changed.
    Room temperature sensor error
    Flashes 2 times in a row every 4 seconds
    E2



    Pipe temperature sensor error
    Flashes 3 times in a row every 5 seconds
    E3
    1. Check the resistance of the temperature sensor, if the resistance of the sensor is out of specification for current temperature, replace the sensor.
    2. Check sensor connection and continuity
    3. The control board is defective, replace the board.

    Outdoor unit error
    Flashes 4 times in a row every 6 seconds
    E4
    1. Check compressor current and winding resistance.
    2. Check the operating pressure. In the event of a refrigerant leak: Remove any remaining refrigerant and repair the leak, evacuate the system and charge according to the scale.
    3. Check the outdoor unit pipe sensor.
    4. Check the condenser of the outdoor unit, it must be clean, free of dust and dirt.
    5. Check the operation of the outdoor unit fan.
    6. The control board is defective, replace the board.
    Indoor fan control error
    Flashes 5 times in a row every 7 seconds
    E5
    1. Check the connectors connecting the fan motor to the control board.
    2. Check the indoor fan motor.
    3. Check the control board components for damage. Replace damaged elements or control board.
    Internal board error
    Flashes 6 times in a row every 8 seconds
    E6
    1. Check the fan of the indoor unit.
    2. Check the output signal from the control board. Replace control board.
    Communication error between blocks
    Flashes 7 times in a row every 9 seconds
    E7
    1. Check the interunit electrical connection.
    2. Check compressor current and winding resistance.
    3. Check the operating pressure.
    overheat protection
    Flashes 8 times in a row every 10 seconds
    E8
    1. Check the filters, they must be clean.
    2. Check the operation of the indoor unit fan.
    3. Check the indoor unit pipe sensor.
    4. Check the operating pressure. In the event of a refrigerant leak: Remove any remaining refrigerant and repair the leak, evacuate the system and charge according to the scale.

    Codes Samsung errors

    Error codes for Samsung air conditioners (Samsung)


    E464 - An overload has occurred in the power module.
    E461 - it is impossible to start the compressor.
    E473 - the compressor has blocked.
    E466 - Incorrect voltage in the DC module of the board.
    E221 - an error has occurred in the sensor responsible for the outdoor temperature
    air.
    E416 - overheating detected.
    E251 - An error has occurred in the temperature sensor.
    E468 - An error has occurred in the current sensor.
    E465 - an error has occurred in the operation of the compressor.
    E237 - An error has occurred in the temperature sensor winding.
    E202 - The time allotted for the connection has expired.
    E458 - An error has occurred in the operation of the fan.
    E471 - an error occurred in the operation of OTP.
    E467 - an error occurred while rotating the compressor.
    E469 - An error has occurred in the voltage sensor.
    E554 - A refrigerant leak has been detected.
    E472 - AC voltage error.
    E121 - short circuit in the sensor responsible for the temperature of the indoor air.
    E122 - short circuit in the sensor responsible for the temperature of the evaporator.
    E154 - An error has occurred in the fan of the indoor unit.
    E101 - connection time exceeded.
    E186 - MPI error fixed.

    Sanyo Error Codes

    Error codes for Sanyo air conditioners (Sanio)

    E01, E05, E14, E17 - an error occurred when receiving a communication signal;
    E02, E04, E06, E10, E20 - an error occurred during the transmission of the communication signal;
    E03 - an error occurred in the remote control;
    E07 - low power level of the indoor unit;
    E08 - there was a duplication of the installation of the addressee of the indoor unit;
    E09 - duplication occurred in the control panel setting;
    E11 - duplication occurred in the implementation of simultaneous multicontrol operations;
    E15 - high power level of the indoor unit;
    E16 - there is no connection of the elements of the indoor unit;
    E18 - an error occurred in the connection with the MDC;
    E31 - errors occurred in the group settings of the indoor unit;
    L01 - types of indoor and outdoor units do not match;
    L02 - in the group control there was a duplication of the main block;
    L03 - there was a duplication of the address in the outdoor unit;
    L04 - a group connection has been made for the indoor unit;
    L07 - address or group not set;
    L08 - power in the indoor unit is not set;
    L09 - an error occurred in setting the power of the outdoor unit;
    L10 - an error occurred in the connection of the control circuits;
    L11 - an error occurred in setting the power of the indoor unit;
    L13 - as a result of connecting the ceiling panel, a failure occurred;
    P01 - malfunctions of the float relay;
    P03 - there were problems with food;
    P05 - no gas;
    P09 - overheating has occurred;
    P10 - there were problems with the discharge temperature;
    P15 - blocked 4-code valve;
    P19 - cooling is overloaded;
    P20 - malfunctions of the outdoor unit fan;
    P22, P26 - failures in the operation of the compressor inverter;
    P29 - errors in the operation of multicontrol when performing simultaneous operations;
    P31 - overload in the compressor;
    H01, F02 - malfunctions of the temperature sensor of the indoor unit;
    F01 - malfunctions of the temperature sensor in the outdoor unit;
    F04, F06, F07 - violation of the temperature mode in the outdoor unit;
    F08 - violations in the intake temperature mode;
    F10 - violations in the discharge temperature mode;
    F12, F29, F31 - errors in the internal non-volatile memory.

    TCL Error Codes

    Error codes for TCL air conditioners (Tcl)

    E0 RUN、TIMER –both winking In and out communication failure. No communication between outdoor and indoor units, check interconnection, indoor and outdoor boards
    EC RUN、TIMER –both winking Outdoor communication failure
    E1 RUN-1 time/8s Outdoor sensor
    E2 RUN-2 times /8s Indoor coil temperature sensor
    E3 RUN-3 times /8s Outdoor coil temperature sensor Faulty condenser temperature sensor
    E4 RUN-4 times /8s System abnormity System abnormal
    E5 RUN-5 times /8s Type mismatch
    E6 RUN-6 times /8s Indoor fan motor
    E7 RUN-7 times /8s Outdoor temperature sensor
    E8 RUN-8 times /8s Discharge temperature sensor Compressor discharge temperature sensor
    E9 RUN-9 times /8s Invert module abnormity
    EF RUN-10 times /8s Outdoor fan motor(DC) Outdoor fan motor
    EA RUN-11 times /8s Current sensor
    EE RUN-12 times /8s EEPROM failure ROM, firmware failure.
    EP RUN-13 times /8s Top of compressor temperature switch
    EU RUN-14 times /8s Voltage sensor
    EH RUN-15/8 sec Intake temperature sensor

    Emergency stop

    P1 RUN: Blink; TIMER: 1 blink /8 sec Overvoltage / undervoltage protection Low/high supply voltage
    P2 RUN: Blink; TIMER: 2 blink /8 sec Overcurrent protection
    P4 RUN: Blink; TIMER: 4 blink /8 sec Exhaust overtemperature protection
    P5 RUN: Bright; TIMER: 5 blink /8 sec Subcooling protection under cooling mode
    P6 RUN: Bright; TIMER: 6 blink /8 sec Overheating protection under cooling mode
    P7 RUN: Bright; TIMER: 7 blink /8 sec Overheating protection under heating mode
    P8 RUN: Bright; TIMER: 8 blink /8 sec Outdoor overtemperature / undertemperature protection Outdoor overheat / undertemperature protection
    P9 RUN: Blink; TIMER: 9 blink /8 sec Drive protection (software control)
    P0 RUN: Blink; TIMER: 10 blink /8 sec Module protection (hardware control)

    Toshiba error codes

    Error codes for Toshiba air conditioners (Toshiba)


    00-0C - an error in the board of the indoor unit or sensor responsible for
    air temperature inside the device.
    00-0d - an error in the control board or sensor responsible for
    radiator temperature.
    00-11 - malfunctions in the motor or fan board.
    00-12 - repair or replacement of the control board is required.
    01-04 - the board or fuses on it burned out, interconnect
    installed incorrectly.
    01-05 - an error has been fixed in the inverter board.
    02-14 - overload detected in the inverter.
    02-16 - there was a short circuit in the compressor windings.
    02-17 - An error has occurred in the current sensor.
    02-18 - an error occurred in the temperature sensors.
    02-19 - An error has occurred in the temperature sensor of the board.
    02-1A - burned out or blocked the motor or board.
    02-1b - a malfunction in the board or sensor responsible for the temperature of the board.
    02-1C - the compressor did not have time to start in the allotted time.
    03-07 - an error has occurred in the inverter board or a defect has been noticed
    coolant.
    03-1d - the compressor is faulty.
    03-1E - an error has occurred in the sensor responsible for the suction tube.
    03-1F - the refrigeration circuit is overloaded or the voltage in the compressor is low.
    03-08 - the four-way valve is faulty.

    There is "CHEK" on the remote control, press it, point the remote control at the air conditioner and scroll through the codes with the temperature arrows, the air conditioner will produce a signal on the fixed codes. So you determine the error code, and you can also reset it. If the error is not critical.

    Zanussi error codes

    Error codes for Zanussi air conditioners (Zanussi)

    Error codes for indication in the indoor unit
    Error code Fault Display indication Remark
    E2 Faulty room temperature sensor TIMER lamp flashes at 5 Hz
    E3 Evaporator sensor fault START lamp flashes at 5 Hz
    E5 Condenser sensor fault Defrost lamp flashes at 5 Hz The system will automatically operate correctly after the fault has been corrected
    F5 Faulty drain pan float switch Alarm lamp flashes at 5 Hz
    F2 Fault in the outdoor unit The defrost and alarm lamp flashes at a frequency of 5 Hz
    P6 EEPROM failure START and TIMER lamp flashes at 5 Hz The system will operate normally after complete shutdown.

    Indication of error codes in the Zanussi outdoor unit
    Fault Indication on the board
    Low pressure protection Flashes 4 times every 6 seconds
    High pressure protection Flashes 3 times every 5 seconds
    Reverse phase protection Flashes 9 times every 11 seconds
    Over current protection Flashing 7 times every 9 seconds
    Outside temperature sensor failure Flashes 5 times every 7 seconds
    Outdoor heat exchanger overheating protection Flashes 2 times every 4 seconds
    Defrost protection Flashing 1 time every 3 seconds
    EEPROM error Flashes 8 times every 10 seconds

    Domestic and industrial air conditioning systems, in most cases, have a self-diagnostic function. This function can work by itself, in auto mode or in a special mode in case there is a problem with the equipment. Information with error codes can be seen on the display located on the indoor unit of the split system.

    E1 - increased pressure in the discharge of the compressor;
    E2 - freezing of the heat exchanger of the indoor unit has occurred;
    E3 - the pressure in the compressor discharge has decreased;
    E4 - the temperature of the discharge pipeline has increased;
    E5 - operation of the compressor current relay;
    F0 - there are malfunctions in the air temperature sensor inside
    room, in the heat exchanger in the indoor unit or ambient air
    in the outdoor unit;
    E6 - there were malfunctions in switching;
    E8 - the engine of the indoor unit is overloaded;
    F1 - there are malfunctions in the temperature sensor in the heat exchanger;
    F4 - there are malfunctions in the temperature sensor of the injected air
    air room.
    H1- is not an error. The air conditioner has switched to auto defrost mode.

    Error codes for air conditioners Ballu (Balu)

    E1 - short circuit or open circuit of the sensor responsible for the indoor unit.
    E2 - short circuit or open circuit of the sensor responsible for the temperature of the condenser.
    E3 - short circuit or open circuit of the sensor responsible for the temperature of the evaporator.
    E4 - short circuit or open circuit of the sensor responsible for the indoor unit.
    E6 - the protection of the external unit has tripped.
    E8 - electrostatic filter clogged.
    P4 - an error has occurred in the operation of the evaporator sensor due to high or
    low temperature.
    P5 - an error has occurred in the operation of the capacitor sensor due to high or
    low temperature.
    P6 - the defrost mode has been switched on or there has been a delay in operation
    heat exchanger.

    Error codes for Carrier air conditioners

    2 - there were malfunctions of the temperature sensor in the room;
    3 - there were malfunctions of the temperature sensor in the internal
    heat exchanger;
    6 - there were malfunctions in the operation of the reversing valve in the outdoor unit;
    8 - there were malfunctions in the fan motor located in
    indoor unit;
    9 - no power supply of the indoor unit;
    11 - there were malfunctions in the drainage pump;
    12 - there was a software failure in the indoor unit;
    13 - an error occurred in the configuration;
    14 - lost signal in the central control system;
    15 - there were malfunctions of the temperature sensor in the internal
    heat exchanger;
    18 - there were malfunctions in the control of the outdoor unit;
    20 - the position of the block is not recognized;
    21 - there were malfunctions of the current sensor located in the outdoor unit;
    22 - there were malfunctions of the temperature sensor in the outdoor
    heat exchanger;
    23 - there were malfunctions of the discharge temperature sensor;
    24 - there were malfunctions in the operation of the fan in the outdoor unit;
    26 - other malfunctions in the outdoor unit;
    27 - the compressor located in the outdoor unit has blocked;
    28 - the value of the discharge temperature is unacceptable;
    29 - there were malfunctions in the compressor, located in the outdoor unit;
    31 - there was an increase in pressure in the circuit of the outdoor unit.

    Error codes for Daikin air conditioners (Daikin)

    A0 - safety device tripped.
    A1 - PCB failure.
    A2 - the fan motor is blocked.
    A3 - abnormal level of drainage.
    A4 - malfunctions in the heat exchanger.
    A5 - abnormal temperature in the heat exchanger.
    A6 - the fan motor is overloaded.
    A7 - Faulty shutter drive.
    A8 - current overload of the device.
    A9 - expansion valve is defective.
    AA - engine overheated.
    AH - air filter contamination.
    AC - idling is fixed.
    AJ - insufficient performance.
    AE - weak water supply.
    AF - humidifier defect detected.
    C0 - the sensor is faulty.
    C3 - the sensor responsible for the drainage system is faulty.
    C4 - the sensor responsible for the temperature of heat exchanger 1 is faulty.
    C5 - the sensor responsible for the temperature of heat exchanger 2 is faulty.
    C6 - the fan motor is overloaded.
    C7 - the sensor responsible for the blind drive is faulty.
    C8 - the sensor responsible for the input current is faulty.
    C9 - Faulty inlet air thermistor.
    CA - the outlet air thermistor is defective.
    CH - high level of pollution.
    CC - humidity sensor is defective.
    CJ - the temperature sensor located on the control panel is faulty.
    CE - the radiation sensor is defective.
    CF - the sensor responsible for high pressure is faulty.

    Error codes for the outdoor unit of Daikin air conditioners (Daikin)

    E0 - a protective device has tripped.
    E1 - the printed circuit board located in the outdoor unit is faulty.
    E3 - triggering of the sensor responsible for high pressure.
    E4 - triggering of the sensor responsible for low pressure.
    E5 - overheating relay or compressor motor overloaded.
    E6 - the compressor motor is blocked.
    E7 - the fan motor is blocked.
    E8 - current overload detected.
    E9 - the expansion valve is faulty.
    AH - a pump blockage has occurred.
    EJ - operation of an additional protective device.
    EE - the permissible water level has been exceeded in the drainage system.
    EF - the unit responsible for the accumulation of heat is faulty.
    H0 - general malfunction of the sensors.
    H1 - the sensor responsible for the air temperature is faulty.
    H2 - the sensor responsible for the electrical supply is faulty.
    H3 - the sensor responsible for high pressure is faulty.
    H4 - the sensor responsible for low pressure is faulty.
    H5 - activation of the overload sensor or the compressor does not work.
    H6 - activation of the blocking sensor or the compressor is overloaded.
    H7 - activation of the blocking sensor or the fan is overloaded.
    H8 - triggering of the sensor responsible for the input voltage.
    H9 - triggering of the sensor responsible for the outdoor temperature.
    HA - triggering of the sensor responsible for the outlet air.
    HH - triggering of the sensor responsible for blocking the water pump.
    HС - triggering of the sensor responsible for hot water.
    HE - triggering of the sensor responsible for the drainage system.
    HF - an accident has occurred in the heat storage unit.
    F0 - actuation of devices No. 1 and No. 2, responsible for protection.
    F1 - actuation of device No. 1, which is responsible for protection.
    F2 - actuation of device No. 2, which is responsible for protection.
    F3 - too high temperature in the discharge pipe.

    Error codes for Dantex air conditioners (Danteks)

    E1 - an error occurred in the non-volatile memory;
    E2 - there was a zero crossing error;
    E3 - no control of the fan speed of the indoor unit;
    E4 - the overvoltage protection mode is in effect;
    E5 - there is no contact with the control of an open temperature sensor;
    E6 - there is no contact with the control of the evaporator temperature sensor.

    Chillers Dantex (DN)

    E0 - an error occurred in the operation of the water flow meter;
    E1 - an error occurred when connecting the phases;
    E2 - a communication error has occurred;
    E3 - an error has occurred in the outlet water temperature sensor;
    E4 - an error has occurred in the temperature sensor of the water at the outlet of
    shell and tube heat exchanger;
    E5 - an error in the operation of capacitor A;
    E6 - an error in the operation of the capacitor B;
    E7 - an error has occurred in the outdoor air temperature sensor;
    E8 - an error has occurred in the charge air temperature sensor;
    E9 - an error occurred in the flowmeter;
    EA - the main block revealed a decrease in the number of additional blocks;
    EB - malfunctions of the frost protection system;
    EC - failures in the operation of the drive controller;
    ED - an error occurred in the control system and communication between the blocks;
    Ed - operation of electrical protection;
    EE - an error has occurred in the connection between the microprocessor and the control panel;
    EF - an error occurred in the inlet water temperature sensor;
    RO - overheating or increased pressure;
    P1 - pressure in system A has decreased;
    P2 - increased pressure or overheated air in system B;
    P3 - the pressure in the system has decreased;
    P4 - there was an overcurrent in system A;
    P5 - there was an overcurrent in system B;
    P6 - increased pressure in the condenser of system A;
    P7 - increased pressure in the condenser of system B;
    P8 - malfunctions in the operation of the compressor discharge temperature sensor in system A;
    Pb - frost protection;
    PE - the temperature in the heat exchanger has decreased;
    F1 - errors in the work of permanent memory;
    F2 - errors in the operation of wired controllers.

    Error codes for Elektrolux air conditioners (Electrolux)

    E1 - the pressure level is exceeded;
    E2 - the indoor unit has frozen;
    E3 - too low pressure level;
    E4 - malfunctions of the compressor;
    E5 - an overcurrent has occurred;
    E6 - there is no connection between the indoor and outdoor units;
    E7 - there was a conflict in the operating modes of the indoor units;
    E8 - the fan of the indoor unit is overloaded;
    E9 - the drainage bath is overflowing;
    F0 - malfunctions in the operation of the temperature sensor in the indoor unit;
    F1 - malfunctions in the operation of the temperature sensor inlet to the heat exchanger
    in the indoor unit;
    F2 - malfunctions in the operation of the temperature sensor in the middle part

    F3 - malfunctions in the operation of the temperature sensor at the outlet of
    heat exchanger in the indoor unit;
    F4 - malfunctions in the operation of the ambient air temperature sensor;
    F5 - malfunctions in the operation of the temperature sensor of the outdoor unit;
    F6 - malfunctions in the operation of the temperature sensor inlet to the heat exchanger
    in the outdoor unit;
    F7 - malfunctions in the operation of the temperature sensor of the exit from
    heat exchanger in the indoor unit;
    F8 - malfunctions in the operation of the discharge temperature sensor of the first
    compressor;
    F9 - malfunctions in the operation of the discharge temperature sensor of the second
    compressor;
    FA - malfunctions in the operation of the crankcase temperature sensor of the 1st compressor;
    FB - malfunctions in the operation of the crankcase temperature sensor of the 2nd compressor;
    FC - malfunctions in the operation of the high pressure sensor;
    FD - malfunctions in the operation of the low pressure sensor;
    EH - malfunctions in the operation of the additional heater.

    Error codes for Fuji air conditioners (Fuji)

    E00 - an error occurred in the connection of the remote control with the indoor unit;
    E01 - an error occurred in the connection between the indoor and outdoor modules;
    E02 - malfunctions of the room temperature sensor;
    E03 - a short circuit has occurred on the room temperature sensor;
    E04 - an error occurred in the operation of the temperature sensor on the internal
    heat exchanger;
    E05 - a short circuit has occurred on the temperature sensor of the internal
    heat exchanger;
    E06 - an error occurred in the operation of the temperature sensor on the outdoor
    heat exchanger;
    E07 - a short circuit has occurred on the outdoor temperature sensor
    heat exchanger;
    E08 - the supply of electrical energy is interrupted;
    E09 - there was an overflow of the tank intended for collecting condensate;
    E0R - malfunctions in the operation of the temperature sensor of the outdoor unit;
    E0B - a short circuit has occurred on the temperature sensor of the outdoor unit;
    Е0С - opening of the temperature sensor on the drain pipe is required;
    E0D - a short circuit has occurred on the temperature sensor of the drain pipe;
    E0F - the output temperature is too high or too low;
    E11 - malfunctions of the control board;
    E12 - malfunctions of the fan of the indoor unit;
    E13 - giving incorrect signals by the system;
    E14 - error in non-volatile memory.

    Error codes for General Climate air conditioners (General Climate)

    E2 - short circuit or open circuit of the sensor responsible for the temperature of the internal
    air.
    E3 - short circuit or open circuit of the sensor responsible for the temperature of the evaporator.
    E4 - short circuit or open circuit of the sensor responsible for the temperature of the condenser.
    E5 - an error has occurred in the operation of the drainage pump.
    E6 - an error in the protection of the external unit.
    E7 - An EEPROM error has occurred.
    E8 - the overflow protection of the drain pan has tripped.

    Error codes for Gree air conditioners (Gri)

    E1 - the compressor protection against too high pressure has tripped.
    E2 - the frost protection of the indoor unit has worked.
    E3 - the compressor protection against too low pressure has tripped.
    E4 - the protection of the injection tube against high temperature has tripped.
    E5 - the protection of the system or compressor against overloads has worked.
    E6 - problems have been detected in the signal or power cables.
    E7 - contradictions in the established mode.
    E8 - the protection of the electric motor or evaporator against overheating has tripped.
    E9 - protection against cold air entry during heating has worked.
    E0 - protection of the frequency controller from too low starting
    voltage.
    H6 - no feedback from the fan motor.
    F0 - the temperature discharge sensor is faulty.
    F1 - the sensor responsible for the evaporator temperature is faulty.
    F2 - the sensor responsible for the temperature of the condenser is faulty.
    F3 - the sensor responsible for the air temperature in the system is faulty.
    F4 - the sensor responsible for the temperature of the supercharger is faulty.
    F5 - the sensor responsible for the compressor discharge pipe is faulty.
    F6 - Capacitor overheating detected.
    F7 - oil carryover from the compressor is detected.
    F8 - protection of the system or compressor from overloads has worked.
    F9 - the compressor protection against high temperatures has worked.
    FF - no power in one of the phases or the phase monitor is faulty.
    H1 - defrosting is in progress.
    H2 - protection of the electrostatic filter has tripped.
    H3 - protection against severe overheating has tripped.
    H4 - A system failure has occurred.
    H5 – IPM block protection operation.
    H7 - malfunctions in the compressor.
    H8 - operation of the drainage system protection against overflow.
    H9 - electrical heater malfunctions.
    H0 - overheat protection trip.
    FA - operation of the condenser or evaporator protection against overheating.
    FH - activation of the evaporator frost protection.

    Error codes for Green air conditioners (Green)

    U1 - Current phase fault, circuit detection for compressor. Flashes 13 times. During cooling and drying operation, the compressor will stop while the indoor fan is running. When running in heating mode, the full unit will stop. Replacement of the external control panel AP1.

    U3 - Malfunction voltage dropping on the DC bus. Flashes 20 times. During cooling and drying operation, the compressor will stop while the indoor fan will run; When operating in heating mode, the full unit will stop.
    The supply voltage is unstable.

    U5 - Malfunction of the full unit of current detection. Flashes 13 times. During cooling and drying operation, the compressor will stop while the internal fan is running; During heating operation, the full block will stop the operation. There is a circuit malfunction on the outdoor units control panel AP1, please replace the outdoor unit control panel AP1.

    U7 - Blinks 20 times. If this fault occurs during heating operation, the device will stop working. 1. The power supply voltage is lower than AC175V; 2. Wiring terminal 4V is loose or broken; 3. 4V will be damaged, please replace the cable.

    U8 - Zero transition inspection circuit malfun-fiction Fan moto pin. Flashes 17 times every 3s Remote controller operation or
    the control panel is available, but the units will not function. The discharging speed of the capacitor is slow, which lead to wrong decision of the controller. Zero crossing detection circuit of the main board abnorma. Refer to flowchar repair.

    U9 - Zero crossing outdoor unit malfunction. Flashes 18 times. During cooling operation, the compressor will stop when the indoor fan is running; during heating, the device will not work. Replacement of the external control panel AP1.

    Error codes for Hitachi brand air conditioners (Hitachi)

    01 - malfunction of the reversing valve or out of order
    media temperature.
    02 - the mode is activated, forcibly starting the external module.
    03 - there is no communication between the external and internal module.
    04 - equipment malfunctions, you should pay attention to the readings
    other indicators.
    06 - violations were detected in the operation of the pump, which pumps out condensate.
    07 - requires manual start of the pump.
    08 - engine functions are violated.
    09 - no communication with the PCB thermistor.
    10 - incorrect fan operation.
    13 - PCB does not function.

    Error codes for Hyundai air conditioners (Hyundai)

    0 – error in non-volatile memory;
    E1 - an error occurred in the connection of the blocks: indoor and outdoor;
    E2 - malfunctions of the sensor of the outdoor unit;
    E3 - malfunctions of the fan motor of the indoor unit;
    E4 - an open (short circuit) of the indoor air temperature sensor has occurred;
    E5 - there was a break (short circuit) of the evaporator temperature sensor;
    EC - A coolant leak has occurred.

    With Gree air conditioners and split systems, repairs are easier than with hi-fay series models.

    Self-diagnosis of Gree air conditioners

    What explains this, the layman asks?

    The explanation is simple Gree: codes. On Gree air conditioners and split systems, there are not many protection system sensors. Those. everything is simplified.

    • Internal self-diagnosis of Gree air conditioners unified and almost identical in error positions to inexpensive air conditioners, such as Pioneer, General Climate, Lessar and others.

    You will laugh, but for example, the catalog of Supra air conditioners has not even changed the name of the outdoor unit, perhaps there are not enough skills in Photoshop, perhaps they did not consider it necessary.

    In a word, how were Supra air conditioners certified in Russia? It's a mystery to me. Supra Catalog!! In faith. Heh...

    Self-diagnosis of Gree air conditioners is, -

    • high pressure protection
    • protected from freezing of the evaporator,
    • Compressor overload protection,
    • Errors in switching the air conditioner during installation, confusing wires,
    • And errors of temperature sensors of the evaporator and condenser.

    Everything, agree not much. Gree, like an air conditioner, is functionally simple, so there are not many error codes.
    There are drawbacks to this simplification - these are weak control board varistors, insufficient smoothing

    Error codes table, continued.

    currents during voltage surges. A trifle, but it must be borne in mind when repairing air conditioners Gree and their analogues.

    Example: country house. The owners, leaving the dacha, usually de-energize the building with a common switch.
    Those. extinguished and everything, calmed down. We arrived ... They turned on the light with the same switch, and the air conditioner, refrigerator, or other Appliances does not work. Why? The answer is simple.

    When the power is turned on with a load, current and voltage surges occur.

    Varistors that smooth out voltage surges cannot cope with the current load and burn out, burn well with smoke and soot, in the absence of a protective sheath, as a rule, together with the fuse of the control board of the indoor unit of the split system.

    There are "specialists" who use wire when burning a fuse. Can you do that? It is possible, but then, in addition to the varistors, the control board, the fan motor of the indoor unit will also burn out, and ... it rushed up to the compressor windings of the outdoor unit of the air conditioner.

    Fireworks at the cottage. - Expensive repairs.

    Troubleshooting and breakdowns of the air conditioner, Gree: codes, as usual, we start with ...

    - refrigeration circuit malfunctions,

    - malfunctions of the electrical part, system e-mail. power supply and air conditioning control.
    Source:

    Error map, mapping. Primary diagnostics of the system.

    GREE Semi-industrial, industrial air conditioners, - error codes.

    Error Code = E1
    Compressor, pressure surges (beep).

    Error Code = E2
    Faulty coil

    Error code = E3
    Low pressure air conditioning compressor activated (beep)

    Error code = F0
    Faulty room temperature sensor.

    Error code = F1
    Incorrect sensor resistance.

    Error code = F2

    • The temperature sensor of the outdoor unit of the air conditioner has tripped.

    Error code = F3
    Temperature sensor circuit open.

    GREE Split air conditioners Error code...

    The cause of the malfunction, - the refrigerant system is highly protected, - pressure.
    code = E1

    Gree LED blinks 1 time.
    Indicator, - cooling =
    Heating indicator =

    The cause of the Gree malfunction is frost protection.
    code = E2

    Air conditioner start LED = LED blinks 2 times.
    Indicator, - cooling =
    Heating indicator =

    Cause of the malfunction, - Compressor exhaust high temperature protection.
    code = E4

    Air conditioner start LED = flashes 4 times
    Indicator, - cooling =
    Heating indicator =

    Cause of malfunction, - AC overcurrent protection
    code = E5

    Air conditioner start LED = LED blinks 5 times
    Indicator, - cooling =
    Heating indicator =

    The cause of the malfunction is a communication failure between the indoor unit of the air conditioner and the outdoor unit of the split system.
    code = E6

    Gree air conditioner start LED = blinks 6 times
    Indicator, - cooling =
    Heating indicator =

    Cause of malfunction, - Anti-high temperature protection
    code = E8

    Air conditioner start LED = flashes 8 times
    Indicator, - cooling =
    Heating indicator =

    The cause of the malfunction, - No feedback from the internal fan motor
    code = H6

    Air conditioner start LED = flashes 11 times
    Indicator, - cooling =
    Heating indicator =

    Cause of the malfunction, - Jumper cap faulty protection
    code = C5

    Air conditioner start LED = flashes 15 times
    Indicator, - cooling =
    Heating indicator =

    Cause of malfunction, - Closed ambient sensor open, no contact or short circuit
    code = F1

    Indicator, - cooling = LED flashes 1 time
    Heating indicator =

    Name of sensor malfunction or failure = Indoor tube open, no contact or short circuit
    code = F2

    Air conditioning start LED =
    Indicator, - cooling = LED flashes 2 times
    Heating indicator =

    The cause of the malfunction, - the external ambient sensor is open, there is no contact or a short circuit
    code = F3

    Air conditioning start LED =
    Indicator, - cooling = LED flashes 3 times
    Heating indicator =

    Cause of malfunction, - Outer tube sensor open, no contact or short circuit
    code = F4

    Air conditioning start LED =
    Indicator, - cooling = flashes 4 times
    Heating indicator =

    Name = malfunction or failure of the exhaust sensor open, no contact or short circuit
    code = F5

    Air conditioning start LED =
    Indicator, - cooling = LED flashes 5 times
    Heating indicator =

    Cause of malfunction, - Over load limit / frequency reduction
    code = F6

    Air conditioning start LED =
    Indicator, - cooling = Blink 6 times
    Heating indicator =

    Cause of malfunction, - Over current limit / frequency output
    code = F8

    Air conditioning start LED =
    Indicator, - cooling = flashes 8 times
    Heating indicator =

    The cause of the malfunction, - High exhaust gas temperature limit / frequency reduction
    code = F9

    Air conditioning start LED =
    Indicator, - cooling flash = 9 times
    Heating indicator =

    The cause of the malfunction, - Overvoltage protection for Ru
    code=PH

    Air conditioning start LED =
    Indicator, - cooling = flashes 11 times
    Heating indicator =

    Cause of the malfunction, - alternating current detection of faulty circuits
    code = U5

    Air conditioning start LED =
    Indicator, - cooling = flashes 13 times
    Heating indicator =

    The cause of the malfunction, - Compressor reverse protection
    code = U4

    Air conditioning start LED =
    Indicator, - cooling = flashes 14 times
    Heating indicator =

    The cause of the malfunction, - Over the compressor phase current protection
    code = P5

    Air conditioning start LED =
    Indicator, - cooling = flashes 15 times
    Heating indicator =

    The cause of the malfunction is the inlet of the malfucntion by the sensor tube
    code = b5

    Air conditioning start LED =
    Indicator, - cooling = flashes 19 times
    Heating indicator =

    The cause of the malfunction, - The open DC fan motor is defective.
    code = L3

    Air conditioning start LED =
    Indicator, - cooling = flashes 21 times
    Heating indicator =

    Cause of the malfunction, - Output malfunction or breakage of the tube sensor
    code = b7

    Air conditioning start LED =
    Indicator, - cooling = flash 22 times
    Heating indicator =

    The cause of the malfunction, - The compressor overload sensor is defective.
    code=FE

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator =

    Cause of malfunction - Defrosting
    code=h3

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator = LED blinks 1 time

    The cause of the malfunction is static dust protection cleaning
    code = H2

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator = LED blinks 2 times

    Cause of malfunction, - Compressor overload protection
    code = H3

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator = LED flashes 3 times

    Cause of malfunction, - System abnormal protection
    code = H4

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator = flashes 4 times

    The cause of the malfunction, - IPM protection
    code = H5

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator = LED flashes 5 times

    Cause of malfunction - PFC protection
    code=HC

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator = flashes 6 times

    Cause of malfunction, - Compressor step loss protection
    code = H7

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator flash = 7 times

    Cause of malfunction, - Heating against high frequencies temperature drop
    code=HO

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator = flashes 10 times

    Cause of malfunction - Startup failure
    code = Lc

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator = flashes 11 times

    Cause of malfunction, - Phase failure protection compressor
    code = U2

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator = flashes 12 times

    Cause of the malfunction, - Phase current compressor faulty detection circuits
    code = U1

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator = flashes 13 times

    Cause of malfunction, - Compressor degaussing protection
    code=HE

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator = flashes 14 times

    The cause of the malfunction, - EEPROM loading is defective.
    code=EE

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator = flashes 15 times

    The cause of the malfunction is a communication failure between motherboard and board drivers
    code = P6

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator = flashes 16 times

    The cause of the malfunction is a malfunction of the charge capacitor
    code=PU

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator = flashes 17 times

    The cause of the malfunction is the IPM of the sensor circuit is faulty.
    code = P7

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator = flashes 18 times

    The cause of the malfunction, - IPM high-temperature protection
    code = P8

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator = flashes 19 times

    Cause of the malfunction, - PN protection voltage drop
    code = U3

    Air conditioning start LED =
    Indicator, - cooling = flashes 20 times
    Heating indicator =

    The cause of the malfunction is low voltage protection PN
    code=PL

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator = flashes 21 times

    Cause of the malfunction, - The current detection circuit is faulty or the current sensor is faulty or broken
    code = Rs

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator =

    The cause of the malfunction, - Compressor phase failure protection
    code = Ld

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator =

    Cause of malfunction, - Compressor or rotary protection blocked
    code=LE

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator =

    The cause of the malfunction, - IPM is more than the temperature limit / frequency reduction
    code=EU

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator =

    Cause of malfunction, - 4-way reversal valve abnormal
    code = U7

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator =

    The cause of the malfunction is the shutdown of the exhaust gas temperature sensor
    code = U8

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator =

    Cause of malfunction, - AC zero voltage error detection
    code = U9

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator =

    The cause of the malfunction, - Over the tube frequency temperature difference
    code=FA

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator =

    Cause of the malfunction, - Anti-freeze limit / frequency reduction
    code=FH

    Air conditioning start LED =
    Indicator, - cooling =
    Heating indicator =

    Models: brand air conditioner repair KFR-32GW/BP, KFR-45LW/D, KFR-3502GW/BP, KFR-2501GW, KFR-45LW, KFR-3301GW, KFR-3201GWCPU, KFR-2608GW/BP and other KFR series, PDF fail.